Specifications
System type . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . Pressurised, pump-assisted thermo-syphon with
front mounted
radiator and electric cooling fan
Pressure cap rating
Up to 1986:
1.1 litre OHV engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . 0.9 bar (13.0 lbf/in2)
1.3 and 1.6 litre CVH engine . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . 0.85 to 1.1 bar (12.0 to 15.7 lbf/in2)
1986 onwards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 0.98 to 1.2 bar (14.2 to 17.0 lbf/in2)
Thermostat
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . Wax
Start to open temperature . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . 85° to 89°C (189° to 192°F)
Fully open temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 102°C (223°F) (±3°C/5°F for used thermostats)
Torque wrench settings Nm lbf ft
Radiator mounting bolts:
Pre-1986 models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 7 to 10 5 to 7
1986 models onwards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . 20 to 27 15 to 20
Thermostat housing bolts:
OHV engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 17 to 21 13 to 16
CVH engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 9 to 12 7 to 9
Water pump bolts:
OHV engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 7 to 10 5 to 7
CVH engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 7 to 10 5 to 7
Water pump pulley (OHV engines) . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . 9 to 11 6 to 8
Fan shroud to radiator:
Pre-1986 models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 7 to 10 5 to 7
1986 models onwards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . 3 to 5 2 to 4
Fan motor to shroud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 9 to 12 7 to 9
See also:
Trip computer components - removal and refitting
1 Disconnect the battery negative lead
Computer module
2 Remove the single screw from the top edge
of the facia panel in which the module is
housed, then withdraw the facia panel.
3 Remove the fo ...
Thermo-viscous cooling fan (SOHC models) - removal and refitting
Removal
1 Disconnect the battery negative lead.
2 Remove the four retaining clips and
unscrew the two retaining screws, then
withdraw the upper section of the fan shroud
(see illustrations).
1 ...
Fuel filter renewal - fuel injection engines (Every 24 000
miles or 2 Years)
Warning: This procedure may
result in some fuel spillage. Before
carrying out any operation on the
fuel system refer to the
precautions given in Safety First! at the
beginning of this manual and ...